Cosel is one of the world's leading power supply manufacturers offering
high-quality, ultra small size AC-DC power supplies,
DC-DC converters of the state-of-the-art technologies, and effective and
easy-to-use noise filters.

Select your language | English | Japanese | Chinese | Korean | German | French |  
Home>Technical Data>FAQ TECHNICAL DATA

Frequently Asked Questions

Q.What is meaning of (L) and (N) on AC terminal?
 There are two different name, L (Live) and N (Neutral) on the AC input terminal. Please refer to Fig. 1 for the wiring of the AC input. The terminal L must be connected to the unearthed conductive part of AC main supply and the terminal N must be connected to the earthed conductive part of AC main supply, to apply the safety agency approval. This purpose is protection by a blowout fuse from electric shock by earth fault.
 Also, the terminal FG needs to be connected to the earth to protect from electric shock and noise interference. Even if the terminal L and the terminal N is connected to another side or the terminal FG is not connected to the earth, then the power supply might not get broken and might not change its characteristic.


The wiring of the AC input

Fig.1 The wiring of the AC input






COSEL CO.,LTD.
COPYRIGHT(c) 2006 COSEL CO., LTD. ALL RIGHTS RESERVED.