2. In case of Abnormal Output Voltage(Too High, Too Low, Unstable) - what to check
| When output voltage is unstable. | |||
| Check Points | Solutions | Applicable Products | |
| There is oscillation caused by remote sensing. - 1 Are the sensing wires too long? |
Use electrolytic capacitor between output terminal (±V, ±M) and sensing terminal (±S). |
R150U, P100E-P(T)1500, UAW, UAF, LDA300, PAA100F-PAA600F | |
| There is oscillation caused by remote sensing. - 2 Are the sensing wires twisted? |
Twist the wires. | ||
| Minimum output current required is not drawn. In case of some Multiple output type power supply, a minimum drawing current is required on +5V output. Check to see if there is minimum load requirement for the power supply. |
(1)Draw a minimum current required on +5V. (2)Use a power supply whose +5V output has no minimum drawing current requirement. |
1)PMC, MMC 2)MMB, LEB,RMB, RMC,LDC | |