Home>Technical Data>Troubleshooting Tips TECHNICAL DATA

1. In case of No Output - what to check
2. In case of Abnormal Output Voltage(Too High, Too Low, Unstable) - what to check

1. In case of No Output - what to check

Output Side
Check PointsSolutionsApplicable Products
1)Wrong connection.
2)Loosened terminal screws. - 1

Is the wiring to the load correct? (For example, +V and -V are connected reversely).
Correct the connection. All Series
1)Wrong connection.
2)Loosened terminal screws. - 2

Check to see if the wiring to the load shorted together accidentally.
Correct the problem by checking the wiring isolation.
1)Wrong connection.
2)Loosened terminal screws. - 3

Terminal screws have loosened?
Tighten the terminal screws.
Overvoltage protection has been operated. - 1
Is output voltage adjuster (trim pot) excessively turned clockwise?
Switch off the power supply, turn output voltage adjuster to its maximum counterclockwise, and wait for 5 minutes before switching on the power supply again. All Series
Overvoltage protection has been operated. - 2
Sensing terminal screws have loosened?
Tighten the screws. R100U, R150U,
P100E-P(T)1500,
UAW, UAF,
PAA100F-PAA600F
LDA300
Overvoltage protection has been operated. - 3
Is sensing wiring correct?
Connect the sensing wires according to the instruction manual.
Overvoltage protection has been operated. - 4
Are sensing wires disconnected?
Re-connected.
Overcurrent protection has been operated.
Are there any chances that the drawing current has become greater than the rated output current?
Check the rated output current of the power supply used and measure the current actually drawn from power supply. All Series
Remote ON/OFF is off. - 1
In case of AC/DC power supply: Is RC terminal connected to RCG terminal?
Connect (short circuit) RC terminal to RCG terminal. P300E,P600E,
P(T)1500,
PAA300F,600F
Remote ON/OFF is off. - 2
In case of DC-DC power supply: Is RC terminal connected to -V input?
Connect (short circuit) RC terminal to -V input. ZUS, ZUW,DAS
Power supplies used in series operation.
Are the power supplies used allowed series operation?
Change the power supplies to those allowed series operation. Refer to instruction manuals.